On 16 May 2026, the International Electrotechnical Commission (IEC) Technical Committee 115 (TC115) published Technical Report IEC/TR 63452:2026, introducing two newly mandated verification items for HVDC converter valve type tests: ‘wideband harmonic tolerance (2–5 kHz)’ and ‘AI-based fault prediction data interface (MQTT over TLS 1.3)’. This development directly impacts manufacturers, system integrators, and grid operators involved in HVDC transmission projects—particularly those active in emerging markets where the report is already being referenced in procurement specifications.
On 16 May 2026, IEC TC115 issued IEC/TR 63452:2026. The document specifies that wideband harmonic tolerance (2–5 kHz) and an AI fault prediction data interface compliant with MQTT over TLS 1.3 must be verified during HVDC converter valve type testing. Although classified as a Technical Report—not a full International Standard—the document has been formally adopted into technical bidding requirements by national grid companies in Brazil, India, and South Africa for 2026 procurements. Leading Chinese manufacturers including XJ Electric and Rongxin Power Electronics have confirmed initiation of adaptation and development work.
Manufacturers are directly required to validate new performance criteria in type testing. Impact arises from both design modification (e.g., filter redesign for 2–5 kHz harmonic suppression) and firmware/software integration (e.g., implementing secure MQTT/TLS 1.3 endpoints for predictive analytics data exchange).
Integrators must verify compliance across full valve stacks and control systems. The new interface requirement implies revised system architecture documentation, cybersecurity validation protocols, and updated test plans for factory acceptance tests (FAT) and site commissioning.
In Brazil, India, and South Africa, this TR is now embedded in tender specifications. Operators face implications for long-term asset monitoring strategy, data governance frameworks, and interoperability expectations between vendor-specific AI models and existing SCADA or digital twin platforms.
Laboratories accredited for HVDC valve testing must now demonstrate capability to perform wideband harmonic injection and measurement (2–5 kHz), and validate secure IoT-style data interfaces—including TLS 1.3 handshake, payload structure, and topic subscription semantics per MQTT v3.1.1 or v5.0.
While Brazil, India, and South Africa have incorporated IEC/TR 63452:2026 into 2026 tenders, its inclusion in EU, ASEAN, or GCC grid codes remains unconfirmed. Stakeholders should track national standardization body announcements (e.g., ABNT, BIS, SABS) and updates to IEC 62749 or IEC 63184.
The TR mandates an ‘AI fault prediction data interface’, but does not specify functional scope (e.g., remaining useful life estimation vs. incipient fault classification) or model validation methodology. Firms should clarify whether conformance requires third-party model audit or only interface protocol compliance.
Validation of 2–5 kHz harmonic tolerance may require new snubber designs, gate-drive isolation enhancements, and wideband current sensors. Procurement teams should engage component suppliers early to confirm availability, lead times, and qualification status of parts supporting this frequency range.
Projects referencing this TR will likely require interface description documents (e.g., MQTT topic tree, TLS certificate management policy, payload schema in JSON Schema or Avro). Engineering and compliance teams should begin drafting standardized templates aligned with IEC 62541 (OPC UA) and ISO/IEC 27001 annex A.8.23 guidance.
Observably, IEC/TR 63452:2026 signals a structural shift—from purely electrical performance validation toward integrated cyber-physical assurance in HVDC assets. Analysis shows this is less a finalized regulatory outcome and more a coordinated policy signal: it reflects growing operator demand for operational intelligence, while remaining technically flexible enough to accommodate diverse AI implementation approaches. From an industry perspective, the rapid uptake in emerging markets suggests these requirements are being treated as de facto standards ahead of formal standardization pathways. Current adoption appears driven less by harmonized grid code evolution and more by national grid companies’ strategic priorities around digital twin deployment and lifetime cost optimization.
Consequently, this TR is best understood not as an isolated update—but as an early marker of how HVDC qualification frameworks will evolve to include both electromagnetic compatibility at higher frequencies and secure, standardized data exchange for AI-driven operations.

Conclusion
This publication marks a procedural inflection point in HVDC converter valve qualification—extending verification scope beyond traditional steady-state and transient electrical behavior into domain-specific signal integrity and digital interface reliability. It does not yet constitute a globally binding requirement, but its operationalization in key growth markets means stakeholders must treat it as a near-term technical and contractual reality. Currently, it is more accurate to interpret IEC/TR 63452:2026 as an anticipatory framework—one that reveals emerging expectations for intelligent, data-enabled HVDC infrastructure rather than enforcing a single technological solution.
Information Sources
• IEC/TR 63452:2026, published by IEC TC115 on 16 May 2026
• Public tender documents issued by Eletrobras (Brazil), Power Grid Corporation of India (PGCIL), and Eskom (South Africa) in Q1 2026
• Official statements from XJ Electric and Rongxin Power Electronics confirming development initiation (as reported in industry press releases, May 2026)
Note: Ongoing observation is recommended regarding potential revision of IEC 62749 (HVDC system performance) and alignment with IEC 63184 (digital twin for power systems), which are currently under development and not yet publicly available.